Protection class
IP45
Rated voltage
110-240 V AC
Operating voltage
4.5 V DC
Mains frequency
50-60 Hz
Flow pressure
100-800 kPa
Test pressure water max.
1600 kPa
Test pressure air / inert gas max.
300 kPa
Water temperature max.
30 °C
Flow rate at 1 bar without flow limiter
0.3 l/s
Flow rate at 1 kPa with flow limiter
0.18 l/s
Minimum flow pressure for calculation flow rate
100 kPa
Relative humidity
≤ 100 %
Calculation flow rate
0.23 l/s
Interval flushing Setting range
1-168 h
Interval flush Factory setting
24 h
Dwell time Setting range
3-15 s
Dwell time Factory setting
7 s
Flush time Setting range
1-15 s
Flush time Factory setting
7 s
Click on an intended use to search for other products
For converting existing Geberit urinal flush controls with mains operation and cover plate 16 x 16 cm
For converting existing Geberit urinal flush controls art. no. 115.802.xx.x, 115.825.00.1, 115.837.00.1, 115.817.xx.x
For automatic flush actuation of urinals
Not suitable for converting urinals with a spray head
Click on a property to search for other products
Infrared user detection with background suppression
Dynamic flush time adjustment
Ready for operation after mains connection
Power failure control
Flush release can be deactivated
Functions can be set and queried with Geberit service mobile phone
Device settings and operation with mobile device via integrated Bluetooth® interface
Compatible with Geberit Control App
Can be networked wirelessly with Geberit Gateway via GEBUS converter
Can be networked wirelessly with Geberit Gateway via Bluetooth®
Compatible with Geberit Connect
Infrared control
Solenoid valve
Power supply unit with adapter
Shut-off valve with throttle
Hold-down device
Seals
Fastening material
Power consumption: ≤ 0.5 W
PU1: 1 pc.